Tilda Publishing
Привет, любопытный друг. Да, это Tilda. Потому что мы хотим быстро внедрять и управлять решением, а не ждать
в очереди разработчика. Контроль, предсказуемость и отказоустойчивость — наша главная идея.
 
get@work-system.ru
для запросов и ТЗ
с 9:30 до 18:00

Juniper QFX3008-FAB-CPE-BNDL

Juniper
Form Factor Distributed switch composed of three components:
QFX3500/QFX3600/QFX5100 QFabric Node
QFX3600-I/QFX3008-I QFabric Interconnect
QFX3100 QFabric Director

Dimensions (W x H x D) QFX5100 QFabric Node:
1.72 x 17.36 x 21.47 in (4.37 x 44.09 x 54.54 cm), 1U QFX3500 QFabric Node:
17.25 x 1.75 x 28 in (43.82 x 4.45 x 71.12 cm); 1U QFX3600 QFabric Node:
17 x 1.74 x 19.4 in (43.2 x 4.4 x 49.3 cm); 1U QFX3600-I QFabric Interconnect:
17 x 1.74 x 19.4 in (43.2 x 4.4 x 49.3 cm); 1U QFX3008-I QFabric Interconnect:
17.5 x 36.75 x 32 in (44.45 x 93.34 x 81.28 cm); 21U QFX3100 QFabric Director:
17.5 x 3.5 x 23.75 in (44.45 x 8.89 x 60.33 cm); 2U

Data Rate QFX3000-M: 5.12 Tbps switching capacity
QFX3000-G: 40 Tbps switching capacity

Port Densities From 200 to 6,144 server-facing 10GbE/FCoE ports in a single QFabric System

Latency 3 to 5us across fabric, under typical loads
<1us per QFX3500 or QFX3600 QFabric Node
<!--1us--><!--1us--><!--1us-->
Resiliency QFX3500/QFX3600/QFX5100 QFabric Node:
Redundant power supplies
Redundant fan trays QFX3600-I QFabric Interconnect:
Redundant power supplies
Redundant fan trays QFX3008-I QFabric Interconnect:
Redundant power supplies
Redundant fabric cards
Redundant control boards QFX3100 QFabric Director:
Redundant power supplies
Redundant disk drives

Power Options QFX5100 QFabric Node:
100 to 240 VAC (single phase) at 50/60 Hz or -36 to -72 VDC
Power Consumption: 335 W QFX3500 QFabric Node:
Power feed (voltage): 100 to 240 V AC (single phase) and 50/60 Hz or -40 to -72 V DC
Power consumption (maximum): 365 Watts
Power consumption (nominal): 230 Watts QFX3600 QFabric Node:
Power feed (voltage): 110 to 240 V AC (single phase) and 50/60 Hz or -40 to -72 V DC
Power consumption (maximum): 345 watts
Power consumption (nominal): 255Power consumption (nominal): 255 QFX3600-I QFabric Interconnect:
Power feed (voltage): 100 to 240 V AC (single phase) and 50/60 Hz or -42 to -72 V DC
Power consumption (maximum): 345 watts
Power consumption (nominal): 255 QFX3008-I QFabric Interconnect:
Power feed (voltage): 200 to 240 Volt AC (single phase); 240 Volt (3 Phase)
Power consumption (maximum): 6,420 Watts (fully loaded)
Power consumption (nominal): 4,620 Watts (fully loaded) QFX3100 QFabric Director:
Power feed (voltage): 100 to 240 Volt AC (single phase)
Power consumption (maximum): 476 Watts
Power consumption (nominal): 220 Watts

Operating System Junos

Traffic Monitoring Port-based
LAG port
VLAN-based
ACL-based
Mirror to local and remote destinations (L2 over VLAN)

QoS Policers (ingress and egress): 1,500 per QFX3500/QFX3600/QFX5100 QFabric Node
Queues: 12 per QFX3500/QFX3600/QFX5100 QFabric Node-8 unicast and 4 multicast

MAC Addresses 120,000 – 1,536,000
Jumbo Frames 9216 Bytes
IPv4 Unicast Routes 16,000
Number of VLANs 4,096 active; 4,090 configurable
FCoE/FC FCoE Interfaces: 6,144 max
FC Interfaces: 1,536 max
Transit switch / FIP snooping FCoE sessions: 48,000 max
VF_Ports: 384,000 max
Warranty Juniper standard one-year warranty


Вся поставляемая продукция сертифицирована
Компания Work System является официальным поставщиком

Официальная гарантия.На всё сетевое и серверное оборудование предоставляется гарантия от 1 до 3-х лет, в том числе на снятые с производства позиции.

*Для получения актуальной стоимости оборудования, свяжитесь с нашими специалистами.
Для каждого заказа расчитывается индивидуальное предложение в зависимости от объема заказа, наличия позиций на складе, текущих акций и имеющихся у вас скидок.

Ответим на любой ваш вопрос. Напишите нам на почту, в чат или через форму заказа.
Похожие серверы