Tilda Publishing
Привет, любопытный друг. Да, это Tilda. Потому что мы хотим быстро внедрять и управлять решением, а не ждать
в очереди разработчика. Контроль, предсказуемость и отказоустойчивость — наша главная идея.
 
get@work-system.ru
для запросов и ТЗ
с 9:30 до 18:00

Juniper QFX10016-REDUND-DC

Juniper
Dimensions (W x H x D) QFX10002: 17.4 x 3.5 x 31 in (44.2 x 8.9 x 78.7 cm); 2U
QFX10008: 17.4 x 22.55 x 32 in (44.2 x 57.3 x 81.3 cm); 13U
QFX10016: 17.4 x 36.65 x 35 in (44.2 x 93 x 88.9 cm); 21U

Power Options 100 to 240 VAC (single phase) at 50/60 Hz or -40 to -72 VDC

System Throughput QFX10002-36Q: 2.88 Tbps
QFX10002-72Q: 5.76 Tbps
QFX10008: 48 Tbps (6 Tbps/slot)
QFX100016: 96 Tbps (6 Tbps/slot)

Form Factor Fixed-configuration (QFX10002) and modular (QFX10008 and QFX10016) platforms

Data Rate (switching capacity) QFX10002-72Q: Up to 2 Bpps
QFX10002-36Q: Up to 1 Bpps
QFX10008: Up to 16 Bpps
QFX10016: Up to 32 Bpps

Port Densities QFX10002-72Q: 288 10GbE, 72 40GbE or 24 100GbE
QFX10002-36Q: 144 10GbE, 36 40GbE or 12 100GbE
QFX10008: 1,152 10GbE, 288 40GbE or 240 100GbE
QFX10016: 2,304 10GbE, 576 40GbE or 480 100GbE

Maximum 10GbE Density QFX10002-72Q: 288
QFX10002-36Q: 144
QFX10008: 1152
QFX10016: 2304

Maximum 25GbE/50GbE Densities N/A

Maximum 40GbE Density QFX10002-72Q: 72
QFX10002-36Q: 36
QFX10008: 288
QFX10016: 576

Maximum 100GbE Density QFX10002-72Q: 24
QFX10002-36Q: 12
QFX10008: 240
QFX10016: 480

Resiliency QFX10002-36Q/-72Q: 2/4 hot-swappable AC/DC power supplies; 3 hot-swappable fan trays
QFX10008: 6 hot-swappable AC/DC power supplies; 2 hot-swappable fan trays
QFX10016: 10 hot-swappable AC/DC power supplies; 2 hot-swappable fan trays

Power Consumption QFX10002-72Q: 1,350 W Typical / 1,650 W Maximum (AC)
QFX10002-36Q: 800 W Typical / 1,000 W Maximum (AC)
QFX10008: 9,463 W Typical / 13,747 W Maximum (AC)
QFX10016: 19,899 W Typical / 28,677 W Maximum (AC)

Overlay Services VMware NSX L2/3 gateway
Juniper Contrail L2/3 gateway

Traffic Monitoring Port-based
LAG port
VLAN-based
ACL-based
Mirror to local and remote destinations (L2 over VLAN and GRE)

QoS Queues / Port Eight output queues per port
MAC Addresses QFX10002-36Q: Up to 256,000
QFX10002-72Q: Up to 512,000
QFX10008 / QFX10016: Up to 1,000,000
Jumbo Frames 9,216 Bytes
IPv4 Hosts Up to 2,000,000
IPv4 Unicast Routes 256,000
IPv4 Multicast Routes Up to 128,000
IPv6 Hosts Up to 2,000,000
IPv6 Unicast Routes 256,000
IPv6 Multicast Routes Up to 128,000
Number of VLANs 16,000
ARP Entries QFX10002-36Q: Up to 144,000
QFX10002-72Q: Up to 256,000
QFX10008 / QFX10016: Up to 256,000


Вся поставляемая продукция сертифицирована
Компания Work System является официальным поставщиком

Официальная гарантия.На всё сетевое и серверное оборудование предоставляется гарантия от 1 до 3-х лет, в том числе на снятые с производства позиции.

*Для получения актуальной стоимости оборудования, свяжитесь с нашими специалистами.
Для каждого заказа расчитывается индивидуальное предложение в зависимости от объема заказа, наличия позиций на складе, текущих акций и имеющихся у вас скидок.

Ответим на любой ваш вопрос. Напишите нам на почту, в чат или через форму заказа.
Похожие серверы